您現(xiàn)在的位置:首頁 >> 產(chǎn)品中心 >> 生化試劑、抗體、血清 >> 試劑盒 >> Bio-rad 161-0449銀染試劑盒Silver Stain Plus Kit

銀染試劑盒Silver Stain Plus Kit

  • 更新時(shí)間:  2023-07-24
  • 產(chǎn)品型號(hào):  Bio-rad 161-0449
  • 簡(jiǎn)單描述
  • 銀染試劑盒Silver Stain Plus Kit
    Kit for detection of nanogram quatities of DNA and protein in polyacrylamide and agarose gels, for 13 full-size or 40 mini gels
詳細(xì)介紹

銀染試劑盒Silver Stain Plus Kit

銀染試劑盒Silver Stain Plus Kit說明:

Product identifier
· Trade name: Development Accelerator Reagent
· Article number: 1610448, 1610448EDU
· CAS Number:
497-19-8
· EC number:
207-838-8
· Index number:
011-005-00-2
· Relevant identified uses of the substance or mixture and uses advised against
· Application of the substance / the preparation Laboratory chemicals
· Details of the supplier of the safety data sheet
· Manufacturer/Supplier:
Bio-Rad Pacific Ltd
Unit 1101, DCH Commerical Center
25 Westlands Road
Quarry Bay
Hong Kong phone: 852-2789-3300 852-2789-1257
· Information department: Technical services, customer support.
· Emergency ephone number: 86-21-63052255
2 Hazards identification
· Classification of the substance or mixture
· Classification according to Regulation (EC) 272/2008
Eye Irrit. 2 H319 Causes serious eye irritation.
· Classification according to Directive 67/548/EEC or Directive 1999/45/EC
Xi; Irritant
R36: Irritating to eyes.
· Information concerning particular hazards for human and environment: not applicable
· Label elements
· Labelling according to Regulation (EC) 272/2008
The substance is classified and labelled according to the CLP regulation.
· Hazard pictograms
GHS07
· Signal word Warning
· Hazard statements
H319 Causes serious eye irritation.
· Precautionary statements
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P264 Wash thoroughly after handling.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy
to do. Continue rinsing.
P337+P313 If eye irritation persists: Get medical advice/attention.
(Contd. on page 2)
PRC
Page 2/7
Safety data sheet
according to 1907/2006/EC, Article 31
Printing date 30.09.2011 Revision: 29.09.2011
Trade name: Development Accelerator Reagent
(Contd. of page 1)
DR
· Other hazards
· Results of PBT and vPvB assessment
· PBT: Not applicable.
· vPvB: Not applicable.
3 Composition/information on ingredients
· Chemical characterization: Substances
· CAS No. Description:
497-19-8 sodium carbonate
· Identification number(s):
· EC number: 207-838-8
· Index number: 011-005-00-2
· Additonal information: For the wording of the listed risk phrases refer to section 16.
4 First aid measures
· Description of first aid measures
· After inhalation Supply fresh air; consult doctor in case of complaints.
· After skin contact Generally the product does not irritate the skin.
· After eye contact Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
· After swallowing Induce vomiting and call for medical help.
· Information for doctor
· Most important symptoms and effects, both acute and delayed No further relevant information available.
· Indication of any immediate medical attention and special treatment needed No further relevant information available.
5 Firefighting measures
· Extinguishing media
· Suitable extinguishing agents
CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
· Special hazards arising from the substance or mixture No further relevant information available.
· Advice for firefighters
· Protective equipment: Wear self-contained respiatory protective device.
6 Accidental release measures
· Personal precautions, protective equipment and emergency procedures
Wear protective equipment. Keep unprotected persons away.
· Environmental precautions: Do not allow to enter sewers/ surface or ground water.
· Methods and material for containment and cleaning up: Pick up mechanically.
· Reference to other sections
See Section 7 for information on safe handling
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.
PRC
(Contd. on page 3)
Page 3/7
Safety data sheet
according to 1907/2006/EC, Article 31
Printing date 30.09.2011 Revision: 29.09.2011
Trade name: Development Accelerator Reagent
(Contd. of page 2)
DR
7 Handling and storage
· Handling
· Precautions for safe handling
No special measures required.
Prevent formation of dust.
· Information about protection against explosions and fires: No special measures required.
· Conditions for safe storage, including any incompatibilities
· Storage
· Requirements to be met by storerooms and receptacles: According to product specification
· Information about storage in one common storage facility: Not required.
· Further information about storage conditions: Keep receptacle tightly sealed.
· Specific end use(s) No further relevant information available.
8 Exposure controls/personal protection
· Additional information about design of technical systems: No further data; see item 7.
· Control parameters
· Components with limit values that require monitoring at the workplace: Not required.
· Additional information: The lists that were valid during the creation were used as basis.
· Exposure controls
· Personal protective equipment
· General protective and hygienic measures
Keep away from foodstuffs, beverages and feed.
Immediay remove all soiled and contaminated clothing
Wash hands before breaks and at the end of work.
Avoid contact with the eyes.
Avoid contact with the eyes and skin.
· Breathing equipment:
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use respiratory
protective device that is independent of circulating air.
· Protection of hands: Protective gloves.
· Material of gloves Synthetic gloves
· Penetration time of glove material
The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.
· Eye protection:
Safety glasses
Tightly sealed goggles.
9 Physical and chemical properties
· Information on basic physical and chemical properties
· General Information
· Appearance:
Form: Crystalline powder
Colour: White
(Contd. on page 4)

 

詳細(xì)產(chǎn)品信息可

 

上海力敏實(shí)業(yè)有限公司代理Bio-rad產(chǎn)品,歡迎 
上海力敏實(shí)業(yè)有限公司代理Bio-rad產(chǎn)品,歡迎 


留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7
真实国产乱子伦视频| 熟女人妻av粗壮巨龙| 亚洲精品卡一卡2卡3卡4卡| 亚洲18色成人网站WWW| 欧美老熟妇xb水多毛多| 最近的2019免费中文字幕| 一边摸一边做爽的视频17国产| 国内精品人妻无码久久久影院蜜桃| 国产av一区二区三区最新精品 | 欧美午夜精品久久久久久| 女性自慰网站免费观看| 麻豆一区二区99久久久久| 国产成人久久婷婷精品流白浆| 在线看国产一区二区三区| 18禁无遮挡无码国产免费网站 | 日日碰日日摸夜夜爽无码| 日本爆乳无码一区二区漫画| 欧美成人精品视频在线观看| 蜜桃影片在线播放网站免费观看| 中文字幕av高清片| 国产AV国片精品一区二区| 无线乱码一二三区免费看| 人妻三级日本三级日本三级极| 日本丰满护士爆乳XXXX无遮挡 | 八个少妇沟厕小便漂亮各种大屁股 | 国产精品亚洲日韩欧美色窝窝色欲| 国产成人亚洲精品无码| 熟女国产精品视频一区二区三区 | 欧美性大战xxxxx久久久| 亚洲熟妇AV一区二区三区浪潮| 久久综合狠狠综合久久| 电梯里吸乳挺进我的身体视频 | 夜夜爽一区二区三区精品| 精品无码久久久久国产| 欧美熟乱第1页| 亚洲成AV人片一区二区| 精品无码av无码专区| 国内精品卡一卡二卡三| 成年免费a级毛片| 国产精品乱码久久久久软件| 人妻少妇久久中文字幕一区二区|